As well as those suitable for category i gas fired appliances with b vent or appliances with a draft hood.
Category 1 vent pipe.
1 avoid an excessive number of turns and bends figure 5 and 2 maximize rise.
Venting guidelines for category i gas appliances single appliance vent tables 1 and 2 continued 10.
As stated earlier heat loss through the vent pipe walls can take away from the draft force.
And is approved for such residential and commercial applications as category 1 water heaters boilers furnaces space heaters or wall heaters.
In other words in a category i venting system if.
First consider the ambient temperature of the air around the vent pipe.
Ul 641 standard type l vent 3.
Ul 1738 standard special gas vent for category ii iii iv appliances 6.
Double wall type b gas vent for approved category i natural gas or propane fired appliances gas furnaces heaters fireplaces and boilers in accordance with nfpa 211 standards for chimneys fireplaces vents and solid fuel burning appliances and nfpa 54 the national fuel gas code.
Vent connectors shall not be upsized more than two sizes greater than the listed appliance categorized vent diameter flue collar diameter or draft hood outlet diameter.
Ul 103 standard building heating appliance chimney canada.
The venting tables within this booklet have now been included in the national fuel gas code nfpa 54 ansi z223 1 1999.
That code may also be used to size venting systems for drafthood equipped central furnaces or for fan assisted combustion system central furnaces.
Category i is defined as a gas heating appliance with a flue loss equal or greater than 17 non condensing with a negative vent static pressure.
A category i vent system works by allowing heated flue products to rise vertically so the vent pipe must rise vertically from the boiler vent connection as soon as possible.
Ul 1738 standard special gas vent for category ii iii iv appliances 2.
You should also limit the length of the horizontal flue pipe.
Single wall galvanized pipe 26 gauge is only used as a connector on 70 percent afue and lower gas appliances and all oil appliances.
Ambient temperature two ambients must be considered.
In some cases transrite has been used which may contain asbestos.
The amerivent all metal double wall gas vent is listed as type b by underwriters laboratories inc.
All horizontal runs of vent pipe must rise 1 4 inch per foot of run to maintain proper draft in the vent.
Ul 103 standard building heating appliance chimney swkl vt 5.
Category i vent materials are found with older appliances.
Gama venting tables for category i central furnaces.
Ul 441 standard type b gas vent 4.
Masonry will use vitreous clay liner.